1 |
GND |
Ground for climate control unit (G502) |
|
2 |
Not used |
???? |
|
3 |
TSUN |
Detects sunlight sensor signal |
|
4 |
HUM DATA |
Humidity sensor communication signal |
|
5 |
HUM CLK |
Humidity sensor communication signal |
|
6 |
RFD-P |
Detects potentiometer signal of recirculation control motor (door position) |
|
7 |
BLOWER G |
Outputs power transistor gate voltage |
|
8 |
BLOWER V |
Feedback signal of power transistor drain voltage |
|
9 |
ILLUMI+ |
Power source for illumination |
|
10 |
M-DEF |
Outputs to drive mode control motor to DEF side |
|
11 |
M-VENT |
Outputs to drive mode control motor to VENT side |
|
12 |
IG2 A/C |
IG2 power source |
|
13 |
M-HOT DR |
Output to drive driver's air mix control motor to HOT side |
|
14 |
M-COOL DR |
Output to drive driver's air mix control motor to COOL side |
|
15 |
B-CAN_L |
B-CAN_L communication signal |
|
16 |
B-CAN_H |
B-CAN_H communication signal |
|
17 |
SENSOR 5V |
Outputs sensor 5 V |
|
18 |
TEVA |
Detects evaporator temperature sensor signal |
|
19 |
TAM |
Detects outside air temperature sensor signal |
|
20 |
AMD P DR |
Detects potentiometer signal of driver's air mix control motor (door position) |
|
21 |
AMD P AS |
Detects potentiometer signal of passenger's air mix control motor (door position) |
|
22 |
MODE-P |
Detects potentiometer signal of mode control motor (door position) |
|
23 |
SENSOR COM |
Sensor ground |
|
24 |
ACS |
Outputs A/C on/off signal |
|
25 |
GND |
Ground for climate control unit (G502) |
|
26 |
ILL- (LED) |
Detects illumination control signal |
|
27 |
F/R MTR(FRESH) |
Output to drive recirculation control motor to FRESH side |
|
28 |
F/R MTR(REC) |
Output to drive recirculation control motor to RECIRCULATE side |
|
29 |
M-HOT AS |
Output to drive passenger's air mix control motor to HOT side |
|
30 |
M-COOL AS |
Output to drive passenger's air mix control motor to COOL side |
|
31 |
Not used |
???? |
|
32 |
RR DEF RLY CL- |